Spectroscopy & Electronic Transition Flame Emission
Use a handheld diffraction grating spectroscope to analyze line emission spectra produced by thermally excited metal cations.
Equipment
- Bunsen burner
- Nichrome or platinum loop wire
- Handheld diffraction grating spectroscope
- Cobalt blue glass
- Watch glass
Chemicals
- Concentrated hydrochloric acid (cleaning)
- Lithium chloride (LiCl)
- Sodium chloride (NaCl)
- Potassium chloride (KCl)
- Barium chloride (BaCl₂)
- Strontium chloride (SrCl₂)
Steps
- Clean the wire loop by dipping in conc. HCl and heating in the roaring blue flame until no color persists.
- Dip the clean moist loop into solid lithium chloride and hold in the non-luminous flame edge.
- View the brilliant carmine red flame directly and through a handheld spectroscope.
- Note the discrete spectral lines (e.g. sharp red line at 670.8 nm).
- Repeat for Strontium (crimson), Sodium (doublet yellow 589 nm), Potassium (lilac, use cobalt glass), and Barium (apple green).
- Record wavelength positions on the nanometer spectral scale.
Observations
- Lithium yields sharp crimson flame with a prominent red spectral line at 671 nm
- Sodium exhibits intense golden yellow doublet at 589 nm
- Potassium shows violet-lilac flame with lines in the deep violet and far red
- Strontium produces bright scarlet-red with multiple visible bands
Explanation
Thermal energy from the flame promotes valence electrons to higher quantised energy levels (E₂). When returning to lower orbitals (E₁), energy is emitted as discrete photons according to Planck's equation: ΔE = E₂ - E₁ = hν = hc/λ. The line spectrum serves as an atomic optical fingerprint.
Equation
ΔE = h · c / λ (Planck-Einstein Relation)
Conclusion
Quantized electronic transitions demonstrate atomic shell structures and form the physical basis for analytical flame photometry and astrophysical spectroscopy.
Safety
Concentrated HCl releases acidic fumes; clean loops in a fume hood. Barium salts are toxic.