Redox Titration: Potassium Permanganate vs Iron(II)
Standardize iron(II) ammonium sulfate using potassium permanganate as a self-indicating oxidizing agent in acidic medium.
Equipment
- Burette
- 25 cm³ bulb pipette and safety filler
- Conical flask
- White tile
- Stand and clamp
Chemicals
- Standardized potassium permanganate solution (0.02 mol/dm³)
- Unknown iron(II) sulfate solution
- Dilute sulfuric acid (1 mol/dm³)
- Deionized water
Steps
- Pipette 25.0 cm³ of iron(II) solution into a clean conical flask.
- Add 20 cm³ of 1 mol/dm³ sulfuric acid to provide necessary H⁺ ions.
- Fill the burette with intense purple 0.02 mol/dm³ potassium permanganate.
- Titrate dropwise while constantly swirling the flask.
- The purple color discharges instantly as MnO₄⁻ is reduced to colorless Mn²⁺.
- The end-point is reached when one drop imparts a permanent faint pink tint persisting for 30 seconds.
Observations
- Burette solution is deep magenta/purple
- Color disappears completely upon entering the flask during titration
- Permanent faint blush pink signals the stoichiometric equivalence point
Explanation
Permanganate ion (MnO₄⁻) is strongly reduced in acid: MnO₄⁻ + 8H⁺ + 5e⁻ → Mn²⁺ + 4H₂O. Iron(II) is oxidized: Fe²⁺ → Fe³⁺ + e⁻. Because MnO₄⁻ is deeply colored while Mn²⁺ and Fe³⁺ are virtually colorless at dilute concentrations, KMnO₄ acts as its own internal indicator.
Equation
MnO₄⁻ + 5Fe²⁺ + 8H⁺ → Mn²⁺ + 5Fe³⁺ + 4H₂O
Conclusion
Stoichiometric redox titrations allow precise quantification of transition metal ions without requiring an added dye indicator.
Safety
Potassium permanganate stains skin and bench surfaces brown (MnO₂). Dilute sulfuric acid is corrosive. Wear eye protection.